TM 5-3895-373-20
14.8.
REPLACE/REPAIR BLOWER MOTOR - Continued.
NOTE
There are four blower motors on the
screed. Replacement and repair
procedures are applicable to all of the
blower motors installed on the
screed. Right hand main and
extension screed blower motors are
shown in this procedure. Differences
between right and left blower motors
are addressed in text.
NOTE
When replacing more than one
blower assembly onto main screed
and extension screed, motor rotation
orientation must be observed.
Motors that rotate counterclockwise
must be installed on right main
screed and left extension screed.
Motors that rotate clockwise must be
installed on left main screed and right
extension screed. Refer to motor
label for correct rotation direction.
A.
REMOVE.
1.
REMOVE SCREED COVER PLATES.
a.
Remove and discard self-locking machine
screws (1).
b.
Remove screed cover plate (2) from the
main screed.
c.
Remove screed cover plate (3) from
extension screed.
GO TO NEXT PAGE
14-60