TM 5-3895-371-24 & P(9)Using seal plate assembly (14, fig. 3-56) and a new seal (13) fill the cavity between seallips half full with multi-purpose grease. Position seal (13), plate (14), and gasket (12) on housing, beingcautious not to damage the lip seal. Install upper two capscrews (16) and lockwashers (15). Torque to11 lb-ft (15 N.m).NOTETo check plunger action, introduce compressed air tointernal feed port. Actuate valve spool (7, fig. 3-10)forward and backward from detented position to con-firm free travel to plunger assembly (30).(10)Place a new gasket (9) on pump (or motor) housing using a thin coat of clean tran-mission oil to hold it in place.Figure 3-56. Control Valve Spool with Cam Follower.3-47