TM 5-3895-371-24 & P
(6) Replace O-ring (49) on mounting flange (55), line up bolt holes, and secure assem-
bly (51) to mounting flange (55) with four capscrews (52) and lockwashers (2). Torque bolts to 11 lb-ft
(7) If
trunnion bearings (40, fig. 3-4) were removed from cam
assembly (42) during dis-
assembly, install new trunnion bearings (40) using an arbor press and a 1-1/2 in. plug, pressing against
the lettered side of the trunnion bearing. It is extremely important that the bearing be started straight
into the born. If the bearing cocks at any time during assembly, remove and discard the bearing Sup-
port the cam lug on the under side to avoid bending the lug. Outer face of trunnion bearing (40) should
be pressed flush with outer face of cam assembly (42).
Figure 3-29. Installing Shaft Seal Retainer.
3-28