TM 5-3895-371-24 & P
Installation of Pump Tachometer and Recording Bitumeter Cables. (Refer to fig. 2-28.)
d.
(1) Feed the pump tachometer cable (4) and the recording bitumeter cable (1) up through
holes in floor at rear of cab.
Connect cables to their respective adapters (2) and (5).
(2)
Connect recording bitumeter cable (1) to adapter on bitumeter wheel.
(3)
Connect pump tachometer cable (4) to drive housing off of the hydrostatic pump.
(4)
(5) Trace each cable through, from hole in floor to its termination. Secure as necessary
with tie wraps.
(6) Install bracket (25) to dash panel with screws (23) and lockwashers (24). Thread mount-
ing stand (18) with nut (21) and washer (22) thru bracket (25) into bracket (9). Install capscrew (19),
lockwasher (17) and nut (16). Tighten lock nut (21).
e.
Disconnect cable (1) from adapter (2).
(1)
Remove adapter (2) by removing lock screw (3).
(2)
Remove the recording bitumeter by removing two nuts (26) and plate (28).
(3)
(4) Replace glass (15) if broken by prying off bezel from head (14) and install new glass (15)
and re-crimp on bezel (13).
Installation of Recording Bitumeter. (Refer to fig. 2-28.)
f.
Mount recording bitumeter in bracket (9) and secure with two nuts (26) and lock-
(1)
washers (27).
Install adapter (2) and secure to recording bitumeter with lock screw (3).
(2)
Connect cable (1) to adapter.
(3)
Section XXII. MAINTENANCE OF HYDRAULIC MOTOR UNIVERSAL DRIVE
2-26. Hydraulic Motor Universal Drive.
a.
Remove two capscrews (16) and lockwashers (17) and slide beck chain guard (5).
(1)
Remove nuts (14), lockwashers (15), and capscrews (3).
(2)
Remove hex nuts (12), lockwashers (11), and capscrews (10).
(3)
Lift the universal drive from between the two mounting plates and remove two spacers (2).
(4)
b.
Place universal drive between the two mounting plates and aline bolt holes
(1)
(2) Place two spacers (2) between motor mounting plate and install three capscrews (3),
lockwashers (15), and hex nuts (14).
2-69