TM 5-3895-371-24 & P
(7)
Install cover (59) and secure with sixteen screws (58).
(8)
Install knob (47) and secure with hex nut (45) and flat washer (46).
Removal of 12-Volt Solenoid Valve. (Refer to fig. 2-16.)
c.
(1)
Remove control box cover (59) and knob (47) as described in paragraph 2-20 a, step (1).
(2)
Disconnect nylon tubes (30) and (38) from male run tee (31).
(3)
Disconnect nylon tubes (7) and (8) from two tubing elbows (32).
(4) Remove two capscrews (63), nuts (55), and washers (6) that fasten solenoid valve (53)
to air control box (64). Remove bracket (54) with attached terminal strip (56); then pull out solenoid
valve (53) as far as attaching wires permit.
(5)
Disconnect wires. Tag wires to aid in reassembly. (Refer to fig. 2-18.)
d.
Installation of 12-Volt Solenoid Valve. (Refer to fig. 2-16, 2-17, and 2-18.)
(1) Mount solenoid valve (53) in air control box (64) and position terminal strip bracket
(54) on the solenoid valve with mounting holes lined up. Fasten with two capscrews (63), washers (6),
and nuts (55).
(2)
(3)
Connect nylon tubes (7) and (8) to tubing elbows (32) on solenoid valve (Refer to
(4)
Connect nylon tubes (30) and (38) to solenoid valve (53).
(5)
Install cover (59) and secure with sixteen screws (58).
(6)
Install control knob (47) and secure with nut (45) and washer (46).
Removal of Circular Solenoid Valve. (Refer to fig. 2-16.)
e.
(1)
Remove control box cover (59) and knob (47) as described in paragraph 2-20 a, step (1).
(2) Disconnect nylon tube (27) with male connector (28) and swivel connector (29) from
bottom of air control box; then remove adapter (16) and washer (6).
(3) Disconnect nylon tube (24) with male connector (25) and swivel connector (26) from
bottom of air control box (64); then remove adapter (16) and washer (6).
(4)
Disconnect nylon tubes (38) and (48) from male run tee (31) and male connector (5).
(5)
Disconnect wires from terminal strip (56).
(6)
Remove two assembled solenoid valves (34) and four washers (6).
(7) Disassemble solenoid valves (34) by removing pipe elbows (33), nipples (35), reducer
bushings (36), one male connector (5), male run tee (31), and check valves (37).
Installation of Circular Solenoid Valves. (Refer to fig. 2-16, 2-17, and 2-18.)
f.
(1) Assemble two solenoid valves (34) by installing two pipe elbows (33), nipples (35),
reducer bushings (36), check valves (37), one male connector (5) and male run tee (31) as shown.
2-49