• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
TROUBLE SHOOTING
TROUBLE SHOOTING (continued)

Technical Manual For Distributor, Bituminous Material Truck Mounted, 1500 Gallon (Cce) Page Navigation
  73    74    75    76    77  78  79    80    81    82    83  
img
.
TM 5-3895-356-14&P
TROUBLE SHOOTING (continued)
Loose Air Connection ..................................................................... Tighten
Defective Solenoid.......................................................................... Replace
Defective Wiring - ........................................................................... Check connections
Defective Cylinder Shaft Seal......................................................... Replace
FIFTH WHEEL FAILS TO LOWER
Probable cause
Probable remedy
Wheel frame binding or bent .......................................................... Repair the wheel frame
Loose air connection ...................................................................... Tighten
Defective Solenoid.......................................................................... Replace
Defective Wiring ............................................................................. Check Connections
GAUGES
BITUMETER COUNTER INOPERATIVE
Probable cause
Probable remedy
Drive cable broken ......................................................................... Replace
Defective adapter ........................................................................... Replace adapter
Faulty tachometer........................................................................... Replace
BITUMETER COUNTER POINTER WHIPS
Probable cause
Probable remedy
Fifth wheel broken .......................................................................... Replace
Defective recording bltumeter ........................................................ Replace the bltumeter
Drive cable binding ......................................................................... Lubricate or replace
QUADRANT
QUADRANT LEVER SLOWS OR STOPS PUMP WHEN MOVING FROM "CIRCULATE IN TANK" TO "CIRCULATE IN
BAR"
Probable cause
Probable remedy
Butterfly valve partially closed ........................................................ Open butterfly valve by pulling on control link
Linkage out of adjustment .............................................................. Check relation of quadrant lever position with
nozzle lever position (See page 10)
Manual)
Transfer valve in handspray position.............................................. Set transfer valve in distribute position
78


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.