TROUBLESHOOTING THROTTLE CIRCUIT
TROUBLESHOOTING HYDRAULIC SOLENOIDS

Maintenance Manual For Paving Machine Bituminous Materiel Crawler Mounted Ded Page Navigation
  209    210    211    212    213  214  215    216    217    218    219  
img
TRAVEL CIRCUIT - Continued
Clutches do not pull in
Track switches in travel position.
Voltage checks: (LH side)
(1) 36 to 3 - defective LH travel switch
(2) Relay R6 should be energized - if not, check for bad relay coil or socket, or lack of continuity from 39 to 3.
(3) 21 to 3 - defective R6 relay contact or socket
(4) Check for defective clutch coil - should have 3.5 ohm resistance for standard torque and 1 ohm resistance for
hi-torque
Voltage checks: (RH side)
(1)
37 to 3 - defective RH travel switch
(2)
Relay R7 should be energized - if not, check for faulty relay, socket, or lack of continuity from 39 to 3
(3)
23 to 3 - defective R7 relay contact or socket
(4)
Check for defective clutch coil - should have 3.5 ohm resistance
TROUBLESHOOTING FEED CIRCUIT
LH Feed Conveyor does not run
LH feed conveyor switch in MANUAL. FWD-REV limit switch in FORWARD.
Voltage checks:
(1) 46 to 3 - defective FWD-REV limit switch
(2) 52 to 3 - defective LH conveyor switch
(3) Relay R12 should be energized - if not, check for defective R12 relay coil or socket
(4) 56 to 3 - defective R12 relay contact
(5) If voltage present - check for defective clutch coil
LH Feed Conveyor runs in MANUAL but not in AUTO.
FWD-REV limit switch in FORWARD. One or both track switches in travel.
Voltage checks:
(1) 47 to 3 - defective R6 and/or R7 relay contact
(2) 51 to 3 - defective LH conveyor switch or defective diode
(3) 52 to 3 - defective or tripped LH feed limit switch
RH Feed Conveyor does not run
RH feed conveyor switch in MA NUA L. FWD- REV limit switch in FOR WA RD.
Voltage checks:
(1) 46 to 3 - defective travel switch
(2) 54 to 3 - defective RH conveyor switch
(3) Relay R13 should be energized - if not, check for defective R13 relay coil or socket
(4) 58 to 3 - defective R13 relay contact
(5) If voltage present - check for defective clutch coil
RH Feed Conveyor runs in MANUAL but not in AUTO.
FWD-REV limit switch in FORWARD. One or both track switches in travel.
Voltage checks:
(1) 47 to 3 - defective R6 and/or R7 relay contact
(2) 53 to 3 - defective RH conveyor switch or defective diode
(3) 54 to 3 - defective or tripped RH feed limit switch
Page 25