TRAVEL CIRCUIT - Continued
Track switches in travel position.
Voltage checks: (LH side)
(1) 36 to 3 - defective LH travel switch
(2) Relay R6 should be energized - if not, check for bad relay coil or socket, or lack of continuity from 39 to 3.
(3) 21 to 3 - defective R6 relay contact or socket
(4) Check for defective clutch coil - should have 3.5 ohm resistance for standard torque and 1 ohm resistance for
Voltage checks: (RH side)
(1)
37 to 3 - defective RH travel switch
(2)
Relay R7 should be energized - if not, check for faulty relay, socket, or lack of continuity from 39 to 3
(3)
23 to 3 - defective R7 relay contact or socket
(4)
Check for defective clutch coil - should have 3.5 ohm resistance
TROUBLESHOOTING FEED CIRCUIT
LH Feed Conveyor does not run
LH feed conveyor switch in MANUAL. FWD-REV limit switch in FORWARD.
Voltage checks:
(1) 46 to 3 - defective FWD-REV limit switch
(2) 52 to 3 - defective LH conveyor switch
(3) Relay R12 should be energized - if not, check for defective R12 relay coil or socket
(4) 56 to 3 - defective R12 relay contact
(5) If voltage present - check for defective clutch coil
LH Feed Conveyor runs in MANUAL but not in AUTO.
FWD-REV limit switch in FORWARD. One or both track switches in travel.
Voltage checks:
(1) 47 to 3 - defective R6 and/or R7 relay contact
(2) 51 to 3 - defective LH conveyor switch or defective diode
(3) 52 to 3 - defective or tripped LH feed limit switch
RH Feed Conveyor does not run
RH feed conveyor switch in MA NUA L. FWD- REV limit switch in FOR WA RD.
Voltage checks:
(1) 46 to 3 - defective travel switch
(2) 54 to 3 - defective RH conveyor switch
(3) Relay R13 should be energized - if not, check for defective R13 relay coil or socket
(4) 58 to 3 - defective R13 relay contact
(5) If voltage present - check for defective clutch coil
RH Feed Conveyor runs in MANUAL but not in AUTO.
FWD-REV limit switch in FORWARD. One or both track switches in travel.
Voltage checks:
(1) 47 to 3 - defective R6 and/or R7 relay contact
(2) 53 to 3 - defective RH conveyor switch or defective diode
(3) 54 to 3 - defective or tripped RH feed limit switch