TM 5-3895-373-20
7.11.
REPLACE/REPAIR VOLTAGE TRANSFORMER - Continued.
C.
REMOVE - Continued.
2.
REMOVE RELAYS.
a.
Remove hex head cap screws (22), flat washers
(23), and ground wire terminals (24). Tag wires.
b.
Remove start relay (25) and induction heater
relay (26) from transformer panel (27). Be
careful not to damage wiring.
3.
REMOVE VOLTAGE TRANSFORMER.
a.
With the help of another person to support
transformer panel (27), remove hex nuts (28),
lockwashers (29), flat washers (30), and socket
head cap screws (31). Discard lockwashers.
b.
Remove transformer panel (27) from paving
machine.
c.
Remove hex nuts (32), lockwashers (33), flat
washers (34), and socket head cap screws (35).
Discard lockwashers.
d.
Remove
voltage
transformer
(36)
from
transformer panel (27).
GO TO NEXT PAGE
7-98