TM 5-3895-373-20
C.
REMOVE.
1.
REMOVE ELECTRICAL CONNECTIONS.
Ensure
terminal
studs
are
not
loosened during hex nut removal. If
studs are loosened, ensure they are
hand tightened only. Damage to the
voltage transformer may occur if the
studs are overtightened.
NOTE
It may be necessary to hold jam nuts
with a backup wrench to allow
removal of hex nuts, and to ensure
studs are not loosened.
a.
Use a backup wrench and remove hex nuts (7)
and lockwashers (8) from voltage transformer
ground
and
24
V
terminals.
Discard
lockwashers.
b.
Tag and remove wire terminal G200 (9) from
voltage transformer ground terminal.
c.
Tag and remove wire terminal 167 (10), wire
terminal 160 (11), and wire terminal 161 (12)
from voltage transformer 24 V terminal.
d.
Remove hex nut (18) and lockwasher (19) from
voltage transformer 12 V terminal. Discard
lockwasher.
e.
Tag and remove wire terminals 103 and 159 (20
and 21) from voltage transformer 12 V terminal.
GO TO NEXT PAGE
7-97