7.11.
REPLACE/REPAIR VOLTAGE TRANSFORMER - Continued.
B.
REPAIR - Continued.
4.
INSTALL ELECTRICAL CONNECTIONS.
a.
Reconnect wire terminal 161 (12), wire terminal
160 (11), and wire terminal 167 (10) to voltage
transformer 24 V terminal.
b.
Reconnect wire terminal G200 (9) to voltage
transformer ground terminal.
Do not overtighten nuts installed on
terminal studs. Overtightening can
cause the stud to turn and cause
internal
damage
to
the
voltage
transformer.
c.
Use a backup wrench and install lockwashers (8)
and hex nuts (7) on voltage transformer ground
and 24 V terminals. Using crowfoot wrench,
tighten hex nuts to 100 lb-in (11 Nm).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
d.
Apply electrical insulating varnish to voltage
transformer ground and 24 V terminals.
GO TO NEXT PAGE