Figure 1. Grid Heater Wiring Harness, Relay Grounds -- Removal.
Figure 2. Grid Heater Wiring Harness, Grid Heaters -- Removal.

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  1034    1035    1036    1037    1038  1039  1040    1041    1042    1043    1044  
img
TM 5-3895-385-23-2
0392
Grid Heater Wiring Harness Removal -- Continued.
1. Open plastic covers (Figure 1, Item 11).
2. Remove two nuts (Figure 1, Item 1), lock washers (Figure 1, Item 2), and black cables (Figure 1, Items 7 and
10) from fuse posts (Figure 1, Items 3 and 5). Discard lock washers.
3. Remove two nuts (Figure 1, Item 9), lock washers (Figure 1, Item 8), and black cables (Figure 1, Items 7 and
10) from relay posts (Figure 1, Items 4 and 6). Discard lock washers.
0392-3