Figure 3. Left Pedestal Wiring Harness.
RIGHT PEDESTAL WIRING HARNESS REMOVAL AND INSTALLATION

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  937    938    939    940    941  942  943    944    945    946    947  
img
. .
TM 5-3895-385-23-2
0374
Left Pedestal Wiring Harness Installation -- Continued.
9. Connect two yellow and black wires (Figure 3, Items 2 and 5) and install two screws (Figure 3, Item 4) onto
EMERGENCY STOP connection points (Figure 3, Item 3).
10. Connect white wire and yellow wire (Figure 3, Item 7) onto run/stop toggle switch (Figure 3, Item 6).
11. Connect W12 J9 (Figure 3, Item 13) onto Y1 P1 (Figure 3, Item 12).
12. Connect W12 J10 (Figure 3, Item 14) onto control pedestal display (Figure 3, Item 1).
13. Connect W12 J12 (Figure 3, Item 9) onto W3 J1 (Figure 3, Item 8).
14. Connect W12 J11 (Figure 3, Item 11) onto W7 J1 (Figure 3, Item 10).
END OF TASK
FOLLOW-ON TASK
1. Install cable ties where necessary.
2. Install platform control (WP 0262).
END OF TASK
END OF WORK PACKAGE
0374-7/8 blank