Main Wiring Harness Removal -- Continued.
20. Disconnect W1 J19 (Figure 5, Item 5) from W10 J5 (Figure 5, Item 2).
21. Disconnect W1 J38 (Figure 5, Item 4) from W10 J2 (Figure 5, Item 3).
22. Disconnect W1 J8 (Figure 5, Item 6) from W10 J1 (Figure 5, Item 1).
23. Loosen screw (Figure 5, Item 10), and disconnect W1 J1 (Figure 5, Item 11) from screed controller ECM
(Figure 5, Item 8).
24. Disconnect W1 J35 (Figure 5, Item 13) from Y6 P2 (Figure 5, Item 9).
25. Disconnect W1 J34 (Figure 5, Item 14) from Y5 P3 (Figure 5, Item 12).
26. Disconnect W1 J3 (Figure 5, Item 16) from output module ECM (Figure 5, Item 7).
27. Disconnect W1 J39 (Figure 5, Item 15) from output module ECM (Figure 5, Item 7).
28. Disconnect W1 J5 (Figure 5, Item 18) from Y10 P1 (Figure 5, Item 17).
29. Remove lock nut (Figure 5, Item 19), washer (Figure 5, Item 20), and clamp (Figure 5, Item 21) from access
panel. Route main wiring harness through access panel. Discard lock nut.