• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 2. Electric Generator Hydraulic Solenoid Coil Override.
TWO SPEED HYDRAULIC SOLENOID COIL REMOVAL AND INSTALLATION

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  524    525    526    527    528  529  530    531    532    533    534  
img
. .
TM 5-3895-385-23-2
0313
Electric Generator Hydraulic Solenoid Coil Manual Override Test -- Continued.
1. Turn engine on (TM 5-3895-385-10).
2. Press override button (Figure 2, Item 1) down and turn counterclockwise until the override button extends
slightly from hydraulic solenoid.
3. Observe hydraulic function or pressure being tested.
4. Press override button (Figure 2, Item 1) down and turn clockwise until the override button locks into hydraulic
solenoid.
5. Turn engine off (TM 5-3895-385-10).
END OF TASK
FOLLOW-ON TASK
1. Install left side cover vent (WP 0430).
2. Verify proper operation.
3. Dispose of hydraulic oil and wiping rags In Accordance With (IAW) local Standard Operating Procedure
(SOP).
END OF TASK
END OF WORK PACKAGE