• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
RIGHT SCREED AUG/CONV KEYPAD FAULT
Table 1. Right Screed Aug/Conv Keypad Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  917    918    919    920    921  922  923    924    925    926    927  
img
. .
TM 5-3895-385-23-1
0191
Table 1. Right Screed Aug/Conv Keypad Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Check fault screen for SCREED
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0181.
2. If no fault is found, proceed to
next malfunction.
2. Keypad malfunction.
1. Attach Plus One diagnostic tool
to BMPM (WP 0444, Vol 3).
2. Press and hold for 2 seconds
1. If each key pressed is indicated
each key on right screed
properly in Plus One software,
aug/conv keypad and note
turn keyless engine switch to the
reading in Plus One software
OFF position (TM 5-3895-385-
(WP 0444, Vol 3).
10), and replace screed
controller module Electronic
Control Module (ECM) (WP
0399, Vol 2).
2. If at least one key pressed is
indicated properly in Plus One
software and at least one key is
not indicated properly, turn
keyless engine switch to the
OFF position (TM 5-3895-385-
10), and replace right screed
aug/conv keypad (WP 0241, Vol
2).
3. If no key pressed is indicated
properly in Plus One software,
turn keyless engine switch to the
OFF position (TM 5-3895-385-
10), and proceed to next
malfunction.
3. No power to keypad.
1. Check fault screen for RIGHT
1. If fault is found, turn keyless
SCREED HORN KEYPAD fault.
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next test.
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to malfunction 5.
2. Access fuse box (WP 0277, Vol
2).
0191-2