• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Right Console Lights Keypad Fault Troubleshooting Procedures -- Continued
Table 1. Right Console Lights Keypad Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  914    915    916    917    918  919  920    921    922    923    924  
img
TM 5-3895-385-23-1
0190
Table 1. Right Console Lights Keypad Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) between
to next test.
communication connector Y10
P1 Pin A and Y10 P3 Pin A (WP
0451, Vol 3, Figure 51).
2. If no continuity is present,
replace communication
connector Y10 (WP 0386, Vol 2).
3. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) between
to next test.
communication connector Y10
P1 Pin B and Y10 P2 Pin B (WP
0451, Vol 3, Figure 51).
2. If no continuity is present,
replace communication
connector Y10 (WP 0386, Vol 2).
4. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) between
to next test.
communication connector Y10
P1 Pin B and Y10 P3 Pin B (WP
0451, Vol 3, Figure 51).
2. If no continuity is present,
replace communication
connector Y10 (WP 0386, Vol 2).
5. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) between
to next test.
communication connector Y10
P1 Pin C and Y10 P2 Pin C (WP
0451, Vol 3, Figure 51).
2. If no continuity is present,
replace communication
connector Y10 (WP 0386, Vol 2).
0190-25


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.