Table 1. Right Conveyor Speed Coil Fault Troubleshooting Procedures -- Continued
Table 1. Horn Fails To Sound Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  657    658    659    660    661  662  663    664    665    666    667  
img
. . . . . . . . . . . .
TM 5-3895-385-23-1
0161
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
HORN FAILS TO SOUND
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0372, Vol 2
Personnel Required
WP 0373, Vol 2
91L
WP 0394, Vol 2
Assistant
WP 0399, Vol 2
References
WP 0443, Vol 3
WP 0162
WP 0447, Vol 3
WP 0181
WP 0451, Vol 3
WP 0184
Equipment Conditions
WP 0187
Engine off (TM 5-3895-385-10)
WP 0189
Hydraulic oil cool (TM 5-3895-385-10)
WP 0192
WP 0269, Vol 2
WP 0277, Vol 2
TROUBLESHOOTING PROCEDURES
Table 1. Horn Fails To Sound Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Screed Controller Offline fault
1. Turn keyless engine switch to
indicated on fault screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Attempt to sound horn using
keypad (TM 5-3895-385-10).
3. Check fault screen for SCREED
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0181.
2. If no fault is found, proceed to
next test.
4. Check fault screen for HORN
1. If fault is found, proceed to WP
RELAY fault.
0162.
2. If no fault is found, proceed to
next malfunction.
0161-1