TM 5-3895-385-23-1
0140
Table 1. Right Extension Out Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Disconnect main manifold wiring
harness W10 J14 from right
extension out hydraulic solenoid
(WP 0451, Vol 3, Figure 27).
2. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine.
3. Press right extension out key on
pedestal top (TM 5-3895-385-
10).
4. Measure voltage (WP 0443, Vol
1. If voltage reads a minimum of 22
3) between pin 1 and 2 on W10
Volts Direct Current (VDC),
J14 (WP 0451, Vol 3, Figure 27)
replace right extension hydraulic
while pressing right extension
out key on pedestal top.
2. If voltage reads below 22 VDC,
turn keyless engine switch to the
OFF position (TM 5-3895-385-
10), and proceed to next test.
5. Disconnect main wiring harness
W1 J8 from main manifold wiring
harness W10 J1 (WP 0451, Vol
3, Figure 27).
6. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine.
7. Press right extension out key on
pedestal top (TM 5-3895-385-
10).
8. Measure voltage (WP 0443, Vol
1. If voltage reads a minimum of 22
3) from W1 J8 Pin 9 (WP 0451,
VDC, turn keyless engine switch
Vol 3, Figure 1) to a known good
to the OFF position (TM 5-3895-
ground while pressing right
385-10), and replace main
extension out key on pedestal
manifold wiring harness (WP
top.
0376, Vol 2).
0140-2