TM 5-3895-385-23-1
0135
Table 1. Right Screed Extension Fails to Extend Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Attach hydraulic pressure tester
(WP 0442, Vol 3) to hydraulic
pressure test port on the main
hydraulic manifold (WP 0449,
Vol 3, Figure 3).
3. Start BMPM engine (TM 5-3895-
385-10).
4. Check hydraulic pressure at
1. If hydraulic pressure reads a
hydraulic pressure test port on
minimum of 1800 pounds per
the main hydraulic manifold
square inch (psi) (12,410
while pressing auger raise key
kiloPascals (kPa)), turn keyless
on pedestal top (TM 5-3895-385-
engine switch to the OFF
10).
position (TM 5-3895-385-10),
and proceed to next malfunction.
2. If pressure reads below 1800 psi
(12,410 kPa), turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
5. Hydraulic solenoid malfunction.
1. Attempt manual override test of
1. If test is successful (right screed
right extension extend hydraulic
extension extends), turn keyless
engine switch to the OFF
0312, Vol 2).
position (TM 5-3895-385-10),
and replace right screed
extension extend hydraulic
2. If test fails, turn keyless engine
switch to the OFF position (TM
5-3895-385-10), and proceed to
next test.
2. Attach hydraulic pressure tester
(WP 0442, Vol 3) to hydraulic
pressure at hydraulic fitting REA
on the main hydraulic manifold
(WP 0441, Vol 3).
3. Start BMPM engine (TM 5-3895-
385-10).
0135-3