Table 1. Right Cutoff Fails to Close Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Start BMPM engine (TM 5-3895-
385-10).
4. Check hydraulic pressure at
1. If hydraulic pressure reads a
hydraulic fitting RCB on the main
minimum of 1800 psi (12,410
hydraulic manifold (WP 0441,
kPa), turn keyless engine switch
Vol 3) while pressing right cutoff
to the OFF position (TM 5-3895-
close key on screed control.
385-10), and replace cutoff
hydraulic cylinder (WP 0404, Vol
2).
2. If pressure reads below 1800 psi
(12,410 kPa), turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and replace right cutoff close
Vol 2).
END OF WORK PACKAGE