LEFT CUTOFF CLOSE FAULT
Table 1. Left Cutoff Close Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  551    552    553    554    555  556  557    558    559    560    561  
img
TM 5-3895-385-23-1
0131
Table 1. Left Cutoff Close Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Press left cutoff close key on
pedestal top (TM 5-3895-385-
10).
4. Measure voltage (WP 0443, Vol
1. If voltage reads a minimum of 22
3) between pin 1 and 2 on W10
Volts Direct Current (VDC),
J21 (WP 0451, Vol 3, Figure 28)
replace left cutoff hydraulic
while pressing left cutoff close
solenoid (WP 0312, Vol 2).
key on pedestal top.
2. If voltage reads below 22 VDC,
turn keyless engine switch to the
OFF position (TM 5-3895-385-
10), and proceed to next test.
5. Disconnect main wiring harness
W1 J8 from main manifold wiring
harness W10 J1 (WP 0451, Vol
3, Figure 1).
6. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine.
7. Press left cutoff close key on
pedestal top (TM 5-3895-385-
10).
8. Measure voltage (WP 0443, Vol
1. If voltage reads a minimum of 22
3) from W1 J8 Pin 4 (WP 0451,
VDC, turn keyless engine switch
Vol 3, Figure 1) to a known good
to the OFF position (TM 5-3895-
ground while pressing left cutoff
385-10), and replace main
close key on pedestal top.
manifold wiring harness (WP
0376, Vol 2).
2. If voltage reads below 22 VDC,
turn keyless engine switch to the
OFF position (TM 5-3895-385-
10), and proceed to next
malfunction.
0131-2