TM 5-3895-385-23-1
0127
Table 1. Right Cutoff Fails to Open Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Loss of hydraulic pressure at
1. Check hydraulic hoses from load
1. If leaks or damage is found,
main hydraulic manifold.
sense hydraulic pump to main
replace damaged hydraulic
hydraulic manifold for leaks or
hose (WP 0291, Vol 2).
pinches (WP 0291, Vol 2).
2. If no leaks or damage is found,
proceed to next test.
2. Attach hydraulic pressure tester
(WP 0442, Vol 3) to hydraulic
pressure test port on the main
hydraulic manifold (WP 0449,
Vol 3, Figure 3).
3. Start BMPM engine (TM 5-3895-
385-10).
4. Check hydraulic pressure at
1. If hydraulic pressure reads a
hydraulic pressure test port on
minimum of 1800 pounds per
the main hydraulic manifold
square inch (psi) (12,410
while pressing auger raise key
kiloPascals (kPa)), turn keyless
on pedestal top (TM 5-3895-385-
engine switch to the OFF
10).
position (TM 5-3895-385-10),
and proceed to next malfunction.
2. If pressure reads below 1800 psi
(12,410 kPa), turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
1. Attempt manual override test of
1. If right screed cutoff opens, turn
right cutoff open hydraulic
keyless engine switch to the
OFF position (TM 5-3895-385-
0312, Vol 2).
10), and replace right cutoff
open hydraulic solenoid (WP
0312, Vol 2).
2. If test fails, turn keyless engine
switch to the OFF position (TM
5-3895-385-10), and proceed to
next test.
2. Attach hydraulic pressure tester
(WP 0442, Vol 3) to hydraulic
pressure at hydraulic fitting RCA
on the main hydraulic manifold
(WP 0441, Vol 3).
3. Start BMPM engine (TM 5-3895-
385-10).
0127-3