UNREQUESTED ENGINE SHUTDOWN
Table 1. Unrequested Engine Shutdown -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  379    380    381    382    383  384  385    386    387    388    389  
img
TM 5-3895-385-23-1
0083
Table 1. Unrequested Engine Shutdown -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Connect battery cables (WP
0357, Vol 2).
3. Turn keyless engine switch to
AUX position (TM 5-3895-385-
10), but do not start engine.
4. Check operator screen for
1. If fault(s) displayed, troubleshoot
faults (TM 5-3895-385-10).
all fault(s).
2. If no faults(s) displayed, turn
keyless engine switch to OFF
position (TM 5-3895-385-10),
and proceed to next malfunction.
2. No or low fuel.
Check fuel level in fuel tank(s) (TM
1. If fuel level is adequate, proceed
5-3895-385-10).
to next malfunction.
2. Add fuel to fuel tank(s) as
needed (TM 5-3895-385-10).
3. Intake airflow restricted.
1. Remove air cleaner assembly
(WP 0369, Vol 2).
2. Remove primary and safety air
filter elements (WP 0369, Vol
2).
3. Inspect primary air filter
1. If damaged or dirty, clean or
element (WP 0369, Vol 2).
replace air filter element (WP
0369, Vol 2).
2. If not damaged or dirty, proceed
to next test.
4. Inspect safety air filter element
1. If damaged or dirty, replace
(WP 0369, Vol 2).
safety air filter element (WP
0369, Vol 2).
2. If not damaged or dirty, proceed
to next test.
5. Inspect intake air tube for
1. If blocked, remove blockage from
blockage (WP 0369, Vol 2).
intake air tube.
2. If not blocked, go to next test.
0083-2


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.