Table 1. Engine Failure To Run After Starting -- Continued
ENGINE FLUID LEAKS

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  367    368    369    370    371  372  373    374    375    376    377  
img
TM 5-3895-385-23-1
0080
Table 1. Engine Failure To Run After Starting -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If not damaged or leaking,
proceed to next malfunction.
8. Fuel pump malfunction.
1. Disconnect the fuel drain line
connecting the fuel pump drain
to the fuel return manifold (WP
0448, Vol 3, Figure 54).
2. Attach pressure gauge and
adapter to the fuel drain line
connection (WP 0448, Vol 3,
Figure 49).
3. Start engine (TM 5-3895-385-
1. If drain line pressure is more
10) and run at idle, or if engine
than 2.7 psi (18.6 kPa), turn
fails to start, measure
keyless engine switch to the
pressure while cranking.
OFF position (TM 5-3895-385-
10), and replace fuel pump (WP
0329, Vol 2).
2. If drain line pressure is less than
2.7 psi (18.6 kPa), turn keyless
engine switch to OFF position
(TM 5-3895-385-10), restore to
original condition, and proceed
to next malfunction.
9. Internal engine problem.
Proceed to Corrective Action.
Replace engine (WP 0323, Vol 2).
END OF WORK PACKAGE