Table 1. SPN#627, FMI#12 ? Injector Power Supply Voltage Low -- Continued
SPN# 629, FMI# 12 ? ENGINE ELECTRONIC CONTROL MODULE (ECM) MEMORY HARDWAREOR INTERNAL VOLTAGE SUPPLY CIRCUITS FAILURE

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  227    228    229    230    231  232  233    234    235    236    237  
img
TM 5-3895-385-23-1
0052
Table 1. SPN#627, FMI#12 ― Injector Power Supply Voltage Low -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If fault code(s) SPN#651,
FMI#5; SPN#653, FMI#5;
SPN#652, FMI#5; and
SPN#654, FMI#5 is not
displayed, turn keyless engine
switch to the OFF position (TM
5-3895-385-10), and replace
ECM (WP 0332, Vol 2).
END OF WORK PACKAGE