Table 1. SPN#108, FMI#4 ? Low Voltage at Barometric Pressure Circuit -- Continued
SPN#110, FMI#0 ? COOLANT TEMPERATURE ABOVE NORMAL

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  109    110    111    112    113  114  115    116    117    118    119  
img
TM 5-3895-385-23-1
0025
Table 1. SPN#108, FMI#4 ― Low Voltage at Barometric Pressure Circuit -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If fault code SPN#108, FMI#4
is not displayed, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and replace the engine ECM
wiring harness (WP 0334, Vol
2).
4. Disable fault code.
1. Turn BATTERY DISCONNECT
switch to OFF position (TM 5-
3895-385-10), and wait for 5
seconds.
2. Turn BATTERY DISCONNECT
switch to ON position (TM 5-
3895-385-10).
3. Start engine (TM 5-3895-385-10)
and let it idle for 1 minute.
4. Check active engine faults
1. If fault code SPN#108, FMI#4
screen for fault code SPN#108,
is displayed, turn keyless
FMI#4.
engine switch to the OFF
position (TM 5-3895-385-10),
and replace engine ECM (WP
0332, Vol 2).
2. If fault code SPN#108, FMI#4
is not displayed, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10).
No fault present; restore
equipment to original condition.
END OF WORK PACKAGE
0025-7/8 blank