Figure 1. Left Side Cover Vent.
Air Filter Primary Element Service

Technical Manual For Bituminous Material Paving Machine (Bmpm) Page Navigation
  283    284    285    286    287  288  289    290    291    292    293  
img
.
TM 5-3895-385-10
0021
Air Filter Primary Element Removal -- Continued.
Figure 2. Air Cleaner Assembly.
1. Remove 14 bolts (Figure 1, Item 2), flat washers (Figure 1, Item 4), lock washers (Figure 1, Item 3), and left
side cover vent (Figure 1, Item 1) from side left plate (Figure 1, Item 5), and discard lock washers.
2. Release three latches (Figure 2, Item 3) on air cleaner housing cap (Figure 2, Item 4), and remove air cleaner
housing cap from air cleaner assembly housing (Figure 2, Item 1).
CAUTION
Rough handling of air cleaner primary element will damage element. Failure to comply may cause
damage to equipment.
3. Remove air filter primary element (Figure 2, Item 2) from air cleaner assembly housing (Figure 2, Item 1).
4. Visually inspect secondary air filter element (Figure 2, Item 6) for damage and debris. Notify field
maintenance if damage or debris is found.
END OF TASK