TM 5-3895-373-20
REFERENCE INFORMATION
AUGER/CONVEYOR CIRCUIT
Refer to paragraph 1.21.1 for a functional description of the auger/conveyor
drive circuit
Open center top left and center top right access doors
per TM 5-3595-373-10 to gain access to hydraulic hose,
lines, and fittings.
Open rear top left and rear top right access doors per
TM 5-3895-373-10 to gain access to hydraulic
auger/convey motors.
An internal leakage path inside the motor will cause
the motor to heat up even though the motor shaft is
hesitating, turning very slow, or not turning at all.
Maintenance at the organization level is limited to
replacing electrical coil on auger/conveyor control
valve.
2-309