TM 5-3895-373-20REFERENCE INFORMATIONAUGER/CONVEYOR CIRCUITRefer to TM 5-3895-373-10 for engine starting and equipment operating procedures. Refer to paragraph 2.10 forconnecting and disconnecting STE/ICE-R test set to DCA.This diagnostic maintenance procedure appliesto both the left hand and right hand auger/conveyor systems. If only one side works, usethe procedure to check the side that doesn’twork. If both systems fail, check either the lefthand or right hand system.If the left hand auger/conveyor system fails,always check components in the left hand circuitunless the procedure instructs you to dootherwise. If the right hand auger/conveyorsystem fails, always check components in theright hand circuit unless the procedure instructsyou to do otherwise.WARNINGEnsure all personnel are clear of pavingmachine before engaging control handles.Paving machine may move causing injury ordeath.NOTEAuger/conveyor switches are located on bothscreed controls boxes.2-307