TM 5-3895-373-20REFERENCE INFORMATIONBATTERY/STARTER CIRCUITBATTERY INTERNAL RESISTANCE - STE/ICE-R TEST 73DESCRIPTIONTEST PROCEDURESEvaluates battery condition by measuring batteryvoltage and current simultaneously.1.Set ENGINE CRANK switch on DCA housing to TEST.Shunt: 12258937-12.Make sure all accessory drive functions are turnedOFF.DCA Test Pins: X, Y, V, and W3.Set TEST SELECT switches to 73.Measurement Range: 0 to 999.9 milliohms4.Press and hold TEST button until CAL appears ondisplay.PRE-TEST PROCEDURESRun confidence test per TM 9-4910-571-12&P.5.Release TEST button and wait for offset value toappear on display. If offset value is within -150 to +150milliohms, proceed. If not, refer to DCA troubleshootingPOSSIBLE ERROR MESSAGESin TM 9-4910-571-12&P.E002Transducer not connected.6.Press and release TEST button.E005Offset not performed.7.When GO appears on display, engage starter for 2seconds or until one of the following appears on theE008VTM does not detect battery voltage.display:OFFE013VTM cannot use data received..9.9.9.9E020No first peak information was detected by theVTM.A valid resistance readingAn error messageE021VTM cannot calculate result because currentis over current probe’s range.8.Observe displayed value. Displayed values are inmilliohms. Expected value is 5 to 17 milliohms.NOTE:If .9.9.9.9 is displayed, battery internal resistance is more than the range of the VTM and cannot bemeasured. If E013 is displayed, then check battery connections and correct as necessary. Repeat testprocedures. If E013 persists after 3 tests, VTM cannot perform test.BATTERY RESISTANCE CHANGE - STE/CE-R TEST 75DESCRIPTIONTEST PROCEDURESMeasures the rate of change of battery resistance asan indicator of battery condition.1.Set ENGINE CRANK switch on DCA housing to TEST.Shunt: 12258937-12.Make sure all accessory drive functions are turnedOFF.DCA Test Pins: X, Y, V, and W3.Set TEST SELECT switches to 75.Measurement Range: 0 to 999.9 milliohms per second4.Press and hold TEST button until CAL appears ondisplay.PRE-TEST PROCEDURESRun confidence test per TM 9-4910-571-12&P.5.Release TEST button and wait for offset value toappear on display. If offset value is within - 150 to +150milliohms per second, proceed. If not, refer to DCAtroubleshooting in TM 9-4910-571-12&P.POSSIBLE ERROR MESSAGES6.Press and release TEST button.E002Transducer not connected.E005Offset not performed.E008VTM does not detect battery voltage.7.When GO appears on display, engage starter for 2seconds or until one of the following appears on theE013VTM cannot use data received.Display:OFFE020No first peak information was detected by theVTM..9.9.9.9A valid resistance readingE021VTM cannot calculate result because currentis over current probe’s range.An error message8.Observe displayed value. Displayed values are inmilliohms per second. Expected maximum value is 25milliohms per second.NOTE:If .9.9.9.9 is displayed, battery resistance change is more than the range of the VTM and cannot bemeasured. If E013 is displayed, then check battery connections and correct as necessary. Repeat testprocedures. If E013 persists after 3 tests, VTM cannot perform test.2-123
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business