TM 5-3895-371-24 & P
Section XXV. MAINTENANCE OF QUADRANT
2-29. Quadrant.
a.
Removal. (Refer to fig. 2-32.)
(1)
Remove cotter pin (13) and disconnect piston rod (14).
(2)
Remove cotter pins (3), (9), and (12); then disconnect links (5), (6), and (10). Remove
washers (4), (11), and (8).
(3)
Remove micro actuating switch (2) from its mounting bracket by removing two cap-
screws; then remove two screws and cover from bottom of micro actuating switch (2) to gain access
to wires.
(4)
Disconnect both wires from the micro actuating switch (2); then remove fitting at the
end of micro actuating switch (2) and pull out wire cable.
(5)
Pull micro actuating switch cable out through hole leaving the grommet (1).
(6)
Remove two capscrews (15) and lift off the complete quadrant.
(7) Remove coupling (7).
b.
Installation. (Refer to fig. 2-32.)
(1) Install coupling (7).
(2)
Mount quadrant into coupling (7). Secure quadrant to tank with two capscrews (15).
(3)
Pull cable for micro actuating switch (2) through grommet (1).
(4)
Connect both wires to micro actuating switch terminals and install fitting at the end
of micro actuating switch (2). Install cover on micro actuating switch and secure with two screws.
(5)
Install micro actuating switch (2) on its mounting bracket and Secure with two cap
screws.
(6)
Connect links (5), (6), and (10) to quadrant and secure with washers (11), (4), and
(8) and cotter pins (3), (9), and (12).
(7)
Connect piston rod (14) to quadrant and secure with cotter pin (13).
2-75