TM 5-3895-371-24 & P(10)Remove self-locking nut (31, fig. 3-10), washer (32), and piston assembly (27) fromplunger assembly (30).(11)Inspect four studs (21). Remove only if the threads have been damaged or if the studsare twisted or broken.(12)Remove four capscrews (1, fig. 3-16), lockwashers (2), cover (3), and gasket (4). (Referto fig. 3-10.)Figure 3-16. Control Housing Cover.i. Disassemble Hydraulic Pump (Continued).(1)From both sides of the housing (24, fig. 3-17), remove eight capscrews (25) and eightlockwashers (26). Pull out trunnions (27), gaskets (28) and bearings (29). (Refer to fig. 3-4.)Figure 3-17. Removing Trunnions.3-17