(10)
Remove self-locking nut (31, fig. 3-10), washer (32), and piston assembly (27) from
plunger assembly (30).
(11)
Inspect four studs (21). Remove only if the threads have been damaged or if the studs
are twisted or broken.
(12)
Remove four capscrews (1, fig. 3-16), lockwashers (2), cover (3), and gasket (4). (Refer
to fig. 3-10.)
Figure 3-16. Control Housing Cover.
i. Disassemble Hydraulic Pump (Continued).
(1)
From both sides of the housing (24, fig. 3-17), remove eight capscrews (25) and eight
lockwashers (26). Pull out trunnions (27), gaskets (28) and bearings (29). (Refer to fig. 3-4.)
Figure 3-17. Removing Trunnions.
3-17