TM 5-3895371-24&PTable 3-1. Direct Support and General Support Troubleshooting (Continued).MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION3.PUMP WILL NOT TURN OR TURNS SLOWLY (Continued):Step 5.Low oil level in reservoir.Replenish oil. (Refer to LO 5-3895-371-12.)Step 6.Spray bar control valves set improperly.Reset controls.Section I I I. GENERAL MAINTENANCE3-4. General Repair Practices.a.When maintenance is authorized for a special component or part, and no special tools aregiven in this manual, you should understand that only standard shop practice techniques are requiredto perform the task. Included in this category is the replacement of a drive shaft universal joint as shownin figure 3-1 and the procedure explained in paragraph 2-14-c where only shop tools and techniques arcused.b.Refer to Appendix A for references to other manuals for general maintenance information.(Such as, welding, inspection and maintenance of bearings, etc.)TA075871Figure 3-1.Replace Drive Shaft Universal.3-3