TM 5-3895-371-24&P
(c)
Mount blower on support assembly (38) and secure with four capscrews (40),
lockwashers (39), and nuts (17).
(d)
Connect two lines with attached fittings and gage to fuel pump (35).
(3)
Screw air filter (36) into blower. Install filter element into blower base and secure with
wing nut (37).
(4)
Install blower drive motor (28) as follows:
(a)
Insert motor shaft into half coupling (30).
(b)
Mate half coupling (30) to spider (19).
(c)
Install two capscrews (24) and locknuts (23) that fasten motor to bracket and
secure. Slide half coupling (30) forward until half coupling is fully seated with spider (19) and tighten
setscrew (20).
(d)
Install two O-rings (27) and connect lines (25) and (26) to motor.
k.
Installation of Blower Assembly. (Refer to fig. 2-41.)
(9) and nuts.
Mount rails (10) with assembled blower on platform and secure with four capscrews
(2)
Connect air line (4) and secure with two screws (3).
(3)
Connect fitting (5), and lines (6), (11), (12), and (13); then install pressure gage
(47, fig 2-42).
Section XXXII. MAINTENANCE OF PORTABLE BURNER
2-36. Portable Burner.
a.
Removal. (Refer to fig. 2-53.) The portable burner is contained in a canister on the vehicle
right rear frame rail. To remove it, simply lift it out.
2-103