TM 5-3895-371-24&P(7)Remove the two bearings in the lower case with a suitable puller or press, only if thebearings need replacing.(8)Remove relief valve (fig.2-51).Figure 2-51.Remove/Install Relief Valve.(9)Remove retainer clip and seal (fig. 2-52) from bottom of lower case.Figure 2-52.Remove/Install Lower Case Seal.h.Cleaning and Inspection of Burner Blower Drive Motor.(1)Clean all parts in dry cleaning solution.(2)Inspect needle bearings. Replace bearings if scored.(3)Inspect motor gears and plate (fig. 2-48 and 2-49). Replace motor if these parts aregouged or otherwise defective.2-101