TM 5-3895-371-24&P(b)Remove ten capscrews (14) that fasten blower end cap (15) to blower housingand remove the end cap with attached fuel pump (35) and gasket.inch.(c)Loosen two setscrews (34) and tap fuel pump (35) out approximately one fourth(d)Remove plug (refer to fig. 2-43) and locate an Allen head setscrew through holefor plug; then loosen the setscrew. It may be necessary to rotate fuel pump (35, fig. 2-42) for accessto setscrew.(e)Tap pump shaft out of collar from inside end cap. (Refer to fig. 2-43.) Removedrive key and remove pump assembly.Figure 2-43.Remove/Install Fuel Pump From Blower End Cap.2-95
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business