TM 5-3895-371-24&P
(b)
Remove ten capscrews (14) that fasten blower end cap (15) to blower housing
and remove the end cap with attached fuel pump (35) and gasket.
inch.
(c)
Loosen two setscrews (34) and tap fuel pump (35) out approximately one fourth
(d)
Remove plug (refer to fig. 2-43) and locate an Allen head setscrew through hole
for plug; then loosen the setscrew. It may be necessary to rotate fuel pump (35, fig. 2-42) for access
to setscrew.
(e)
Tap pump shaft out of collar from inside end cap. (Refer to fig. 2-43.) Remove
drive key and remove pump assembly.
Figure 2-43.
Remove/Install Fuel Pump From Blower End Cap.
2-95