TM 5-3895371-10
Section II. OPERATION OF AUXILIARY EQUIPMENT
There is no auxiliary equipment for the Bituminous Distributor.
Section III. OPERATION UNDER UNUSUAL CONDITIONS
2-26. Operation in Extreme Cold.
The distributor is not intended for operation in temperatures below 40F (4C)
2-27. Operation Under Dusty or Sandy Conditions.
a. Air Cleaners. When operating under dusty or sandy conditions, service the air cleaner twice daily, or as
necessary. When the oil becomes dirty, replace with new oil. Thoroughly clean and lubricate the air cleaner as soon as
possible after exposure to dusty or sandy conditions. The unit should be washed thoroughly or steam cleaned, if possible.
b. Lubrication. Lubricate more frequently than specified in LO 5-3895-371-12. Keep all covers on lubrication points
closed
2-28. Operation in High Humidity and Salt Water Areas.
a. General. Salt water corrodes metal. Avoid contact with salt water as much as possible, but after any necessary
contact, clean the complete unit with fresh water.
b. Cleaning. Wash the unit with fresh water under pressure as soon as possible after exposure to salt water.
c. Protection. If the distributor is stored in an area where salt water spray is in the air, use a tarpaulin or portable
shed for protection.
2-38