Figure 8
Figure 9
Press the seal firmly in place and lubricate the lip with
Place the pressure plate on the locating pins and flat
petroleum jelly or other grease compatible with the system
against the ring. Use a small amount of petroleum jelly or
fluid. Slide the drive shaft into the body until the bearing is
grease to stick the spring in the recess In the pressure
seated, Tap lightly on the end of the shaft if necessary.
plate. Carefully install the cover with the outlet port in the
Install the snap ring.
correct position. Tighten the cover screws to the torque
shown in Figure 8. Turn the shaft through by hand to
insure that there is no internal binding. Install the shaft
Install the new "O" rings in the body and cover. Insert
key.
the ring locating pins in the body and assembly the ring so
that the arrow on the perimeter points in the proper
Assemble the pump to its mounting flange or foot
direction of rotation. Check the assembly against Figure 9.
Install the rotor on the shaft and inset the vanes in the rotor
mounting. If a gasket is used, be certain it is flat to avoid
misalignment of the shaft.
slots. Be certain the radius edges of the vanes are toward
the cam ring.
Section VII - TESTING
Vickers Mobile Division application engineering personnel should be consulted for test stand circuit requirements and
construction. If test equipment is available, the pump should be tested at the recommended speeds and pressures
shown on the installation drawings (see Table I).
12