Table 1. Right Cutoff Open Fault Troubleshooting Procedures -- Continued
LEFT CUTOFF FAILS TO OPEN

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  545    546    547    548    549  550  551    552    553    554    555  
img
TM 5-3895-385-23-1
0129
Table 1. Right Cutoff Open Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Check output module ECM for
1. If screed controller module ECM
damage or loose pin.
has damage or loose pin,
replace output module ECM (WP
0399, Vol 2).
2. If no damage is found, proceed
to next malfunction.
4. Main wiring harness has an
Measure for continuity (WP 0443,
1. If continuity is present, proceed
open circuit.
Vol 3) between main wiring harness
to next malfunction.
W1 J3 Pin 1 and main wiring
harness W1 J8 Pin 7 (WP 0451, Vol
3, Figure 1).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
5. Main wiring harness has a short
Measure for continuity (WP 0443,
1. If continuity is present, replace
circuit.
Vol 3) between main wiring harness
main wiring harness (WP 0373,
W1 J3 Pin 1 and all other pins on
Vol 2).
the main wiring harness W1 J3 (WP
0451, Vol 3, Figure 1).
2. If no continuity is present,
replace output module ECM (WP
0399, Vol 2).
END OF WORK PACKAGE