Table 1. SPN#167, FMI#1 ? Electrical Charging System Voltage Low ? Most Severe Level - Continued
SPN#167, FMI#16 ? ELECTRICAL CHARGING SYSTEM VOLTAGE HIGH ? MODERATE SEVERE LEVEL

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  178    179    180    181    182  183  184    185    186    187    188  
img
TM 5-3895-385-23-1
0042
Table 1. SPN#167, FMI#1 ― Electrical Charging System Voltage Low --
Moderately Severe Level -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If resistance is more than 100
kΩ, proceed to next test.
2. Start engine (TM 5-3895-385-
10) and idle for 1 minute.
3. Check active engine fault
1. If fault code SPN#167, FMI#1 is
screen for fault code SPN#167,
displayed, turn keyless engine
FMI#1.
switch to the OFF position (TM
5-3895-385-10). It is possible
that another fault exists or that
another troubleshooting
procedure applies. If this was
the first time through the task,
restore to original condition,
and restart troubleshooting at
malfunction 1.
2. If fault code SPN#167, FMI#1 is
not displayed, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10).
No fault present; restore
equipment to original codition.
END OF WORK PACKAGE