TM 5-3895-373-20REFERENCE INFORMATIONDCA CIRCUITBATTERY/STARTER CIRCUIT - STE/CE-R TESTS 71 THROUGH 75DESCRIPTIONTEST PROCEDURESMeasures the rate of change of battery resistance as an indicatorof battery condition.1.Set ENGINE CRANK switch on DCA housing toTEST.Shunt: 12258937-1DCA Test Pins: X, Y, V, and W2.Make sure all accessory drive functions are turnedOFF.Measurement Range: 0 to 999.9 milliohms per second3.Set TEST SELECT switches to 71, 72, 73, 74, or75.PRE-TEST PROCEDURESRun confidence test per TM 9-4910-571-12&P.4.Press and hold TEST button until CAL appears ondisplay.5.Release TEST button and wait for offset value toappear on display. If offset value is within -150 to+150 milliohms per second, proceed. If not, referto DCA troubleshooting in TM 9-4910-571-12&P.POSSIBLE ERROR MESSAGESE002Transducer not connected.6. Press and release TEST button.E005Offset not performed.7. When GO appears on display, engage starter for 2E008VTM does not detect battery voltage.seconds or until one of the following appears on theE013VTM cannot use data received..9.9.9.9E020No first peak information was detected by theA valid resistance readingVTM.An error messageE021VTM cannot calculate result because current is over current probe’s range.8.Observe displayed value. Displayed values are inmilliohms per second. Expected maximum valueis 25milliohms per second.NOTE:If .9.9.9.9 is displayed, battery resistance change is more than the range of the VTM and cannot be measured. IfE013 is displayed, then check battery connections and correct as necessary. Repeat step 7. If E013 persistsafter 3 tests, VTM cannot perform test.ALTERNATOR OUTPUT VOLTAGE - STE/ICE-R TEST 82DESCRIPTIONTEST PROCEDURESMeasures voltage at alternator output at +24 volt battery terminal.1.Set TEST SELECT switches to 82.DCA Test Pins: V and WMeasurement Range: 0 to 32 Vdc2.Start paving machine, set engine at MAX, and turnall3.Press and release TEST button.PRE-TEST PROCEDURESRun confidence test per TM 9-4910-571-12&P.4.Observe displayed value. Displayed values are involts DC. Expected display value is 26 volts,minimum. If .9.9.9.9 is displayed, voltage is notwithin test range.POSSIBLE ERROR MESSAGESNone2-383
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business