TM 5-3895-373-20
REFERENCE INFORMATION
DCA CIRCUIT
BATTERY/STARTER CIRCUIT - STE/CE-R TESTS 71 THROUGH 75
DESCRIPTION
TEST PROCEDURES
Measures the rate of change of battery resistance as an indicator
of battery condition.
1.
Set ENGINE CRANK switch on DCA housing to
TEST.
Shunt: 12258937-1
DCA Test Pins: X, Y, V, and W
2.
Make sure all accessory drive functions are turned
OFF.
Measurement Range: 0 to 999.9 milliohms per second
3.
Set TEST SELECT switches to 71, 72, 73, 74, or
75.
PRE-TEST PROCEDURES
Run confidence test per TM 9-4910-571-12&P.
4.
Press and hold TEST button until CAL appears on
display.
5.
Release TEST button and wait for offset value to
appear on display. If offset value is within -150 to
+150 milliohms per second, proceed. If not, refer
to DCA troubleshooting in TM 9-4910-571-12&P.
POSSIBLE ERROR MESSAGES
E002
Transducer not connected.
6. Press and release TEST button.
E005
Offset not performed.
7. When GO appears on display, engage starter for 2
E008
VTM does not detect battery voltage.
seconds or until one of the following appears on the
E013
VTM cannot use data received.
.9.9.9.9
E020
No first peak information was detected by the
A valid resistance reading
VTM.
An error message
E021
VTM cannot calculate result because current is over
current probes range.
8.
Observe displayed value. Displayed values are in
milliohms per second. Expected maximum value
is 25
milliohms per second.
NOTE:
If .9.9.9.9 is displayed, battery resistance change is more than the range of the VTM and cannot be measured. If
E013 is displayed, then check battery connections and correct as necessary. Repeat step 7. If E013 persists
after 3 tests, VTM cannot perform test.
ALTERNATOR OUTPUT VOLTAGE - STE/ICE-R TEST 82
DESCRIPTION
TEST PROCEDURES
Measures voltage at alternator output at +24 volt battery terminal.
1.
Set TEST SELECT switches to 82.
DCA Test Pins: V and W
Measurement Range: 0 to 32 Vdc
2.
Start paving machine, set engine at MAX, and turn
all
3.
Press and release TEST button.
PRE-TEST PROCEDURES
Run confidence test per TM 9-4910-571-12&P.
4.
Observe displayed value. Displayed values are in
volts DC. Expected display value is 26 volts,
minimum. If .9.9.9.9 is displayed, voltage is not
within test range.
POSSIBLE ERROR MESSAGES
None
2-383