TM 5-3895-373-20REFERENCE INFORMATIONDCA CIRCUITSTARTER MOTOR VOLTAGE - STE/ICE-R TEST 68DESCRIPTIONTEST PROCEDURESMeasures the voltage present at the starter positive (B)terminal.1.Set TEST SELECT switches to 68.DCA test Pins. T and W2.Turn ignition switch to START position for 10 secondsper TM 5-3895-373-10.Measurement Range: 0 to 32 Vdc3.Press and release TEST button.PRE-TEST PROCEDURESRun confidence test per TM 9-4910-571-12&P.4.Observe displayed value. Displayed values are involts. If .9.9.9.9 is displayed, voltage is not within testrange. Expected minimum display value is 17 volts.POSSIBLE ERROR MESSAGESNoneSTARTER SOLENOID VOLTAGE - STE/ICE-R TEST 70DESCRIPTIONTEST PROCEDURESMeasures the voltage present at the starter solenoid ’S’terminal.1.Set TEST SELECT switches to 70.DCA test Pins: S and W2.Turn ignition switch to START position per TM 5-3895-373-10.Measurement Range: 0 to 32 Vdc3.Press and release TEST button.PRE-TEST PROCEDURESRun confidence test per TM 9-4910-571-1 2&P.4.Observe displayed value. Displayed values are involts. If .9.9.9.9 is displayed, voltage is not within testrange. Expected minimum display value is 18 volts.POSSIBLE ERROR MESSAGESNone2-382