TM 5-3895-373-202.21. DCA CIRCUIT DIAGNOSTICS.These DCA diagnostic tests can be run anytime youthink there is a problem with the paving machine’s DCAor its on board transducers. Do not use this paragraphto test the STE/ICE-R and its cables and transducers.Refer to TM 9-4910-571-12&P to test the STE/ICE-R andfor using the STE/ICE-R in the TK mode to substitute fortests run through the DCA.The following table gives a cross reference betweenDCA tests and TK tests. Use this cross reference to findout how to substitute TK tests for DCA tests if you havesuspect DCA transducer or interconnect wiring. A wiringdiagram of the DCA assembly is provided for referenceon page 2-378. STE/ICE-R test procedures are providedfor reference on pages 2-379 through 2-382.DCA to TK Cross ReferenceDCA TKTEST PARAMETER USE TK TEST MEASUREMENT POINTS10 RPM 34-PULSE TACHOMETERWITH A W4 CABLE10 Put in place of tachometer generator.24 FUEL PRESSURE 17-BLUE PRESSURETRANSDUCER50 Install in place of DCA fuel pressure transmitter.26 FUEL FILTERPRESSURE DROP17-BLUE PRESSURETRANSDUCER50 Install TK pressure transducer in place of DCAdifferential pressure switch. Measure pressure onboth sides of filter; calculate difference If STEACE-Rindicates pass and pressure difference is less than15.5 psi, or if STE/ICE-R indicates fail and pressuredifference is greater than 11.5 psi, DCA differentialpressure switch is OK28 AIR CLEANERPRESSURE DROP22-RED PRESSURETRANSDUCER48 Install in place of DCA air cleaner output pressuretransmitter.30 AIR PRESSURE 22-RED PRESSURETRANSDUCER47 Install in place of DCA turbosupercharger outputpressure transmitter.35 OIL PRESSURE 17-BLUE PRESSURETRANSDUCER50 Install in place of DCA oil pressure transmitter.36 OIL FILTERPRESSURE DROP17-BLUE PRESSURETRANSDUCER50 Install TK transducer in place of DCA oil differentialpressure switch. Measure pressure on both sides offilter; calculate difference. If difference equalsSTE/ICE readout +3.0 psi, DCA differential pressureswitch is OK.38 COOLANTTEMPERATUREN/A N/A Check DCA temperature transducer in boiling water.If temperature indication is from 210.5°to 213.5°F,temperature transducer is OK.67 BATTERY VOLTAGE NONE REQUIRED 67 VTM takes data through W5 (POWER) cable.68 STARTER VOLTAGE W2 CABLE 89 Attach red clip to starter positive terminal, black tobattery side of shunt.70 STARTER SOLENOIDVOLTAGEW2 CABLE 89 Attach red clip to solenoid 'S' terminal, black tostarter case.71 STARTER CURRENT 11-CURRENT PROBE 90 Put probe around negative battery cable between theshunt and the battery.72 CURRENT FIRSTPEAK11-CURRENT PROBE 72 Put probe around negative battery cable between theshunt and the battery.73 BATTERYRESISTANCE11-CURRENT PROBE 73 Put probe around negative battery cable between theshunt and the battery.74 STARTER CIRCUITRESISTANCE11-CURRENT PROBE 74 Put probe around negative battery cable between theshunt and the battery.75 BATTERYRESISTANCECHANGE11-CURRENT PROBE 75 Put probe around negative battery cable between theshunt and the battery.2-375
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business