TM 5-3895-373-20REFERENCEINFORMATION HYDRAULIC CYLINDER CIRCUITSRefer to paragraphs 1.21.1 through 1.21.6 forfunctional descriptions of hydraulic cylindercircuits.Valve repair actions at the unit level are limitedto replacing the valve electrical coil.Open right access door per TM 5-3895-373-10to gain access to stack valve.Hydraulic oil under pressure canpenetrate skin or damage eyes. Oilleaks under pressure may not bevisible. Use a piece of cardboard orwood to find leaks, but do not use abare hand. Wear safety goggles forprotection. If oil enters skin or eye,get immediate medical attention.Open right, center top right, and center top leftaccess doors per TM 5-3895-373-10 to gainaccess to hydraulic hoses, lines, and fittings.2-283