TM 5-3895-373-20REFERENCE INFORMATIONHIGH SPEED SHIFT CIRCUITRefer to TM 5-3895-373-10 for engine starting and equipment operating procedures. Refer to paragraph 2.10 forconnecting and disconnecting STE/ICE-R test set to DCA.The high speed shift valve reverses flow to thehydraulic propulsion motor control ports. Theflow reversal changes the position of a port platein the motor, producing more shaft revolutionsper unit flow.If paving machine starts, circuit breaker CB1 isconducting +12 vdc to the neutral start circuit.Thereby, if high speed shift circuit fails, problemmust be in switch, wiring, solenoid valve, orhydraulic propulsion motor.To avoid reversing polarity to the voltmeter,connect negative test lead to equipment groundand use positive lead to probe for voltage.Open center top right and center top left accessdoors per TM 5-3895-373-10 to gain access tohigh speed shift valve.Refer to paragraph 7.21 for harness and leadwire repair.2-241