TM 5-3895-373-20REFERENCE INFORMATIONPANEL GAUGE CIRCUITRefer to paragraphs 1.18.5 and 1.18.6 forelectrical system description for the panelcontrols and indicators.Refer to paragraph 7.21 for harness and leadwire repair.Refer to the electrical system diagram at the endof the manual for equipment wiring details.Temperature sensor resistance should vary withcoolant temperature as follows:TEMPERATURE:100200250OHMS:3334822After completing diagnostic checks, close fronttop left access door per TM 5-3895-373-10.Install gauge panel per paragraph 7.6.2-197