TM 5-3895-371-24 & P(2) Disconnect air supply line (2, fig. 2-25) from solenoid valve (5).LEGEND:1. AIR CHAMBER 6. NUTS2. AIR SUPPLY LINE 7. SPRING3 QUICK DISCONNECT 8. YOKE LOCKNUT4. SOLENOID GROUND WIRE 9. AIR CHAMBER YOKE5. SOLENOID VALVE 10. CAPSCREW11. MOUNTING BRACKETTA 075831Figure 2-25. Remove/Install Bitumeter Wheel Solenoid Valve and Air Chamber.(3) Disconnect solenoid ground wire (4) by removing capscrew, nut and washer. Pull apartpower line at quick-disconnect (3) and remove air line (2) from solenoid valve (5).(4) Unscrew solenoid valve (5) from air chamber (1).(5) Disconnect spring (7) from air chamber (1).(6) Remove two nuts (6) and washers that fasten air chamber (1) to mounting bracket (11).(7)Remove capscrew (10) and nut that fasten air chamber yoke (9) to wheel fork.(8) Loosen yoke locknut (8); then unscrew the yoke from air chamber (1).(9) Pull air chamber (1) out of mounting bracket (11).2-62
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business