TM 5-3895-371-10
g
Disconnect pump off line.
h
Turn vacu-flo lever straight up to normal position
i.
To blow out hand spray, if desired after spraying, raise intake valve lever, remove filling cap, open hand
spraying valve and push butterfly valve lever in against stop. Add flushing oil if desired.
j.
Reinstall filling cap.
2-15.
a.
Place the control levers (see fig. 2-9 for location) in the following positions
(1)
Quadrant Control Lever - Hand spray
(2)
Butterfly Valve Lever - In
(3)
Intake Valve Lever - Up
(4)
Bar Raising Lever - Up
(5)
Transfer Valve Lever - Hand spray
(6)
Drain Valve Lever - Forward
(7)
Vacu-flo Valve Lever - Up
b.
Hook up hose from supply source to the filling connection using filling line adapter from tool box. Be sure
connections are tight.
c.
Hook up hose from storage to transfer connection using adapter from tool box. Be sure connections are
tight.
d.
Run pump at maximum speed where it will run quietly Normally 150 gpm is best transfer speed.
e.
When through transferring, turn transfer valve lever to Distribute position. Pull butterfly valve lever back
out against stop.
CAUTION
If oil enters distributor tank when transferring, butterfly value is not closed tight.
2-26