TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WARNING
There are many points on the BMPM where personnel could be injured by moving parts. Turn
BMPM off before performing maintenance. Care should be taken to avoid any pinch points when
performing maintenance. Failure to comply may cause injury or death to personnel.
5. Check for obstructed movement.
1. Remove any obstructions
around auger or auger raise
and lower slide.
2. If no obstructions are found,
proceed to next test.
6. Check for proper hydraulic oil
1. Ensure hydraulic oil is at proper
level.
level and temperature, and fill
2. Notify field maintenance if
problem persists.
59. Left or right cutoff fails to open
1. Check for Right Cutoff Open
1. If no fault is found, proceed to
or close.
fault, Right Cutoff Close fault,
next test.
Left Cutoff Open fault, or Left
2. If fault is found, notify field
Cutoff Close fault indicated on
maintenance.
2. Check for proper BMPM setup
2. If conditions are met, proceed
to next test.
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
2. If blown fuse is not found,
proceed to next test.