TM 5-3895-373-20
D.
ASSEMBLE Continued.
i.
Install lockwasher (50) and flat washer (51) onto
hex head cap screw (49).
Sealing
compound
can
cause
eye
damage. Wear safety goggles/glasses
when using. Avoid contact with eyes. If
compound contacts eyes, flush eyes
with water and get immediate medical
attention.
j.
Apply sealing compound to threads of hex head
cap screw (49).
k.
Install vent cover plate (52) and secure with flat
washer (51), lockwasher (50), and hex head cap
screw (49). Tighten cap screw to 9 lb-ft (12
Nm).
Anti-seize compound can cause eye
damage. Wear safety goggles/glasses
when using. Avoid contact with eyes. If
compound contacts eyes, flush eyes
with water and get immediate medical
attention.
1. Apply anti-seize compound to threads of glow
plug (47).
m. Install gasket (48) and glow plug (47). Tighten
glow plug to 33 Ib-ft (45 Nm).